Corrosion Protection Structures for Ground Anchors I, II, and III | Do Temporary Structures Require Backfilling?

Hello, everyone.

This is Enta.

Something caught my attention regarding the grout injection into the mouth of the temporary anchor.

Filling and Injection

It was a temporary anchor, but after the grout was injected, it had sunk about 1 meter.

Well, that's pretty common, so it's not a problem.

So, um...

When I was told to fill this in, I was like, “Huh?”

Filling and Injection 2

As a result, I filled the gaps with mortar, but since it bothered me, I looked into it.

So, here's the thing.

 Corrosion Protection Less than 2 years 2 years or more
Normal Environment Corrosion Protection Structures I Corrosion Protection Structures II
Highly Corrosive Environment Corrosion Protection Structures II Corrosion Protection Structure III

It says so.

Temporary anchors with a service life of two years or lessSoCorrosion Protection Structures IThat’s how it works.

Therefore, when deciding whether to fill this in, I’ve concluded that it isn’t necessary to do so. (In my case)

However, this is ultimately up to the judgment and discretion of the anchor installer.

Even after 20 years in this industry, there are times when I find myself thinking, “Huh???”

Every time I look into it, I learn a lot.

It really is important to get out into the field every once in a while and get a feel for the atmosphere there.

If we keep talking in terms of theoretical concepts, we risk losing touch with what’s actually happening on the ground.

 

And, I went out to the job site today (just to help out for a few hours), but...

It was totally useless lol

 

See you later.

Leave a comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.