Rules for Preparing Test Specimens | Quality Control

Hello, everyone.

This is Enta.

Test specimen

Are you making test specimens? lol

 

Did you know that there are rules governing the preparation of these test specimens?

To be honest, I hadn't really thought much about it because I didn't know enough, but something happened that prompted me to look into it.

 

When preparing test specimens, the grout level drops due to bleeding, right?

If you don't raise the level.

Cement Slurry: Preparation of Test Specimens

If you built it up, you can cut or shave it down later, so I think it should be fine.

You need to be careful if the price drops during the "breathing" phase.

 

The dimensional tolerances for test specimens are,The diameter must be within 0.5 to %, and the height must be within 5 to %.

That's just the way it is.

For a 50 × 100 cement slurry test specimen, this means a diameter of 0.25 mm and a height of 5 mm.

 

Furthermore, there are specific requirements for the thickness of the capping when performing capping on surfaces with a height of 5 mm or less.

The thickness of the capping layer shall not exceed 2 % of the specimen diameter.

In the case of the test specimen mentioned above, the capping thickness is 1 mm or less.

 

That means,It's better to make it a little bigger and then trim it down.So that's how it is.

These days, grinders are so powerful that they can cut through things easily. They’re pretty expensive, though, lol.

Like, 500 to 1,000 yen per side...

 

Still, it's better than not having any strength at all.

By the way, the rules mentioned above are

Preparation of Test Specimens for Concrete Strength Testing JIS A 1132:2014

 

You can find it if you look it up online.

It doesn't hurt to know this, so please be sure to keep it in mind.

 

See you later.